Q
Can you show me details of multi-level collection device for wax collection (heated tubes from graphite box to collector also ?)
A
Yes, DMF will offer multi-level collection device for wax collection (heated tubes from graphite box to collector.
-
Q
The hot water temperature regulation/ heater is also included in control unit of furnace or separate ?
A
The hot water temperature regulation is set separately, while the heater is included in control unit of furnace.
-
Q
Min and max negative pressure for Ar dewaxing ?
A
Negative Pressure for Ar Dewaxing Max= 35mbar Min=5mbar
-
Q
Max Ar pressure for sintering with Argon atmosphere (without diffusion pump) ? 1000 mbar pressure OK ?
A
∴Max Ar pressure for sintering with Ar (without diffusion pump) =40mbar ∴1000 mbar pressure is availabe but will increase at least 10% equipment cost.
-
Q
If sintering in Ar atmosphere, all the furnace is also under Ar atmosphere at same pressure ?
A
It can be regarded as the same pressure although the pressure near the vacuum access is a bit lower which can be ignored.
-
Q
Floor footprint / Overall dimensions of furnace ?
A
DMF will offer the layput as per requirment in details.
-
Q
Requirements (cooling water/compressed air....) ?
A
Cooling Water: 0.1~0.25MPa, diameter 2", 6~8M3/h
-
Q
Ansawdd A oes ei angen ?
-
Q
Ar yr ochr prynu/logisteg, a allech chi roi gwybod i ni beth yw'r Cod HS ar gyfer yr offer (efallai y bydd yn fwy nag un)? Rydym am i'r wybodaeth hon wirio beth yw'r dyletswyddau posibl a gymhwysir i fewnforio'r peiriant.
A
Cod HS (cod 10 digid wedi'i gysoni): 8514109000
-
Q
A allech ddweud wrthyf am y weithdrefn a’r rhagofalon pan fyddwn yn defnyddio’r nwy H2 gyda gwres? Byddai’n ddefnyddiol dweud wrthym beth yw’r gwahaniaeth o gymharu ag achos nwy N2.
A
Oes, gwiriwch y llyfr llaw yn unol â hynny. Mae wedi'i ysgrifennu yn Saesneg a Tsieinëeg